<%@LANGUAGE="JAVASCRIPT" CODEPAGE="936"%> 镇江市太极电动车电源有限公司
 
     Product show
capability and notice proceeding
Your site:-> Zhenjiang Taiji Electric Vehicle Battery Co, Ltd->use and maintenance

   Use of battery
    1 The battery should remove the surface dust and dirty before using, and check damage, if it damaged, we will repair or change according to damage degree. After checking, make up the single battery in battery group according to the need.
    2 confect electrolyte
    2.1 Battery, which stipulated electrolyte density is 1.265±0.005g/cm3(30℃) when begin to discharge, should confect sulphuric acid solution that density is 1.250±0.005g/cm3(30℃) as electrolyte. Compared volume ratio of the sulphuric acid (density is 1.835 g/cm3) with water is about 3.3:1; the mass ratio is about 1.8:1.
    2.2 Battery, which stipulated electrolyte density is 1.270±0.005g/cm3(30℃) when begin to discharge, should confect sulphuric acid solution that density is 1.250±0.005g/cm3(30℃) as electrolyte. Compared volume ratio of the sulphuric acid (density is 1.835 g/cm3) with water is about 3.3:1; the mass ratio is about 1.8:1.
    2.3 Battery, which stipulated electrolyte density is 1.280±0.005g/cm3(30℃) when begin to discharge, should confect sulphuric acid solution that density is 1.265±0.005g/cm3(30℃) as electrolyte. Compared volume ratio of the sulphuric acid (density is 1.835 g/cm3) with water is about 3.1:1; the mass ratio is about 1.7:1.
    2.4 Battery, which stipulated electrolyte density is 1.290±0.005g/cm3(30℃) when begin to discharge, should confect sulphuric acid solution that density is 1.275±0.005g/cm3(30℃) as electrolyte. Compared volume ratio of the sulphuric acid (density is 1.835 g/cm3) with water is about 2.6:1; the mass ratio is about 1.65:1.
    2.5 While confect the electrolyte, should use acidproof and high temperature-resistant container, put water in above-mentioned proportion first, and then add the sulphuric acid in water slowly pro rata, and churn up with the acidproof stick or purgative compressed air at the same time, and make it mix evenly. Don’t pour water into sulphuric acid, avoiding accident occurrence.
    2.6 The electrolyte that has already confected, after cooling under the normal temperature, adjust the density according to following table 。

 

temperature
5
10
15
20
25
30
35
40
density
g/cm3
1.268
1.265
1.261
1.257
1.254
1.250
1.246
1.243
1.283
1.280
1.276
1.272
1.269
1.265
1.261
1.258
1.288
1.285
1.281
1.277
1.274
1.270
1.267
1.263
1.293
1.290
1.286
1.282
1.279
1.275
1.271
1.268
1.298
1.294
1.291
1.287
1.284
1.280
1.277
1.273
1.303
1.300
1.296
1.292
1.289
1.285
1.281
1.278
1.308
1.304
1.301
1.297
1.294
1.290
1.287
1.283
1.313
1.310
1.306
1.302
1.299
1.295
1.291
1.288

copyright:Zhenjiang Taiji Electric Vehicle Battery Co, Ltd